Cover of Movement Related Cortical Potentials Based Brain Computer Interface for Stroke Rehabilitation by Niazi, Imran , Khan, ISBN 9788792982452
Physical Medicine & Rehabilitation

Movement Related Cortical Potentials Based Brain Computer Interface for Stroke Rehabilitation

MOVEMENT RELATED CORTICAL POTE

Contributor(s): Author Format: Paperback

Paperback · ISBN 9788792982452

₹3,144 3%
₹3,225

Inclusive of GST and other taxes

100% Quality Assurance
No Account Creation Required
Fast Delivery
Secured Transactions

Arriving at your doorstep in 10-15 days

Our logisitcs team will make sure everyitem is delivered safely

Key Specifications

ISBN 9788792982452
Subtitle MOVEMENT RELATED CORTICAL POTE
Publisher River Publishers
Publication date December 2012
Language English
MRP £25.00 GBP
Page count 36
Item weight 15 g

A brain-computer interface (BCI) is a system that interprets brain signals generated by the user, allowing specific commands from the brain to be sent to an external device. Such interface enables severely disabled people to interact with their environment without the need for any activation of their normal pathways involved in motor commands. The combination of rehabilitation paradigms and BCIs, both of which exploit cortical plasticity, could help people become "able" once again. For this reason, BCI systems appear promising rehabilitation tools. The aim of this PhD thesis is to study how a BCI system can be used for stroke rehabilitation when it is based on neuromodulation techniques using Hebbian plasticity and movement related cortical potentials (MRCP) with an optimum number of EEG electrodes. Four studies were conducted to achieve this goal: In STUDY I the novel protocol developed in Mrachacz-Kersting et al. 2012 had showed improvement in some relevant clinical measures used to access functionality of motor tasks in stroke population, when applied three times in a week as a training paradigm. These encouraging results from our first study alongside the Mrachacz-Kersting et al. 2012 study served as the basis for development of a self-paced BCI system for induction of plasticity. In STUDY II (pseudo online) detector for self-paced BCI system, based on movement intention detection from initial negative phase of MRCP, was proposed and tested in healthy volunteers and then in STUDY III real online selfpaced BCI system for induction of plasticity was implemented and tested. In STUDY IV a subject independent detector (based on STUDY II) was developed and compared with individualized detector. The results were promising as difference between performances of two approaches was not significantly different.